The GT-32 MkII is the BGO version of the second-generation GT-30/32 MkII handheld gamma-ray spectrometer. It shares the whole platform with the GT-30 MkII — the strong alloy body sealed against dust and water, the removable rubber boot, the large colour trans-reflective sun-readable display, the five-button interface and the well-sealed removable battery cartridge — but carries a 2″ × 2″ BGO crystal read out by a 2″ bialkali photomultiplier. BGO’s much higher density gives a high counting efficiency per unit of crystal volume, and the crystal is not hygroscopic.
2″ × 2″ BGO detector, 104 cm³, 2″ bialkali PMT
High counting efficiency per volume, non-hygroscopic crystal
NORM (KUTh) assay by least squares, up to 6 nuclides
3.5″ trans-reflective colour display, sun readable
IP-65, USB-C, Wi-Fi & Ethernet, built-in GNSS
Like the GT-30 MkII, the GT-32 MkII is built as an open platform, so special features requested by customers can be implemented quickly. The instrument combines an FPGA with a fast, low-consumption ARM processor, and the implemented least-squares method determines the concentration of up to six elements or mixtures — which suits NORM measurements combined with man-made contamination such as Cs-137. Beyond the standard NaI(Tl) and BGO crystals the platform also accepts CsI(Tl), CsI/Eu, GAGG and YAP; when a silicon photomultiplier (SiPM or MPPC) replaces the vacuum tube, the space saved allows crystals up to 2″ × 5″. Typical applications include mineral and rare-earth-metal exploration, uranium exploration, geology and geophysics, environmental monitoring, nuclear facilities, waste recycling, production facilities and construction-material control.
| Parameter | Value | Note |
|---|---|---|
| BGO, ø 51 × 51 mm (2″×2″), 104 cm³ | GT-32 MkII standard option | |
| diameter 2″, bialkali | SiPM array with special-option crystals | |
| NaI(Tl), CsI(Tl), CsI/Eu, GAGG, YAP | ø 51 × max 120 mm with SiPM array | |
| 1024-channel, 40 MHz DSP, pile-up rejector 200 ns | linear energy corrected | |
| 20 keV – 3.0 MeV | 1024 channels, lookup-table linearisation | |
| 160 cps/MBq (Cs-137) at 1 m | quoted for the NaI(Tl) 2″×2″ reference detector | |
| energy-corrected air kerma Ka & H*(10) | 10 nGy/h – 80 µGy/h, specified for NaI detector | |
| 20 samples/s, moving average & integration | acoustic & visual alarm, 4 LED indicators | |
| least-squares fitting of whole spectrum | up to 6 nuclides in a blend, with std. deviation | |
| colour LCD 360 × 240, 72 × 54 mm (3.5″) | trans-reflective, automatic backlight | |
| illuminated 5-position navigation joystick | operable with gloves | |
| 32 GB, min. 8000 samples with full spectra | spectra, profiles, dose, position, voice message | |
| USB-C, Wi-Fi, Ethernet | internal GNSS GPS/QZSS/GLONASS, 56 channels | |
| Li-ion 7.2 V / 6600 mAh | min. 8 h at 20 °C, USB-C 60 W adapter | |
| 290 × 100 × 160 mm, 2.65 kg | IP-65, −10 to +50 °C |
| Model | Scintillator | Crystal size | Photomultiplier |
|---|---|---|---|
| NaI(Tl) | ø 51 × 51 mm, 104 cm³ | vacuum PMT | |
| BGO | ø 51 × 51 mm, 104 cm³ | 2″ bialkali | |
| CsI(Tl), CsI/Eu, GAGG, YAP | ø 51 × max 120 mm (2″ × max 5″) | SiPM / MPPC array |